Issue:
Perfmon on Windows 2003 x64 servers, the object counters are showing as numerical values instead of “processor”, “memory” etc
Solution:
Make sure you have taken a full System Backup before trying the below mentioned steps.
On a 64-bit machine, there are two versions of “lodctr.exe”
– %windir%\system32
– %windir%\SysWow64
You have to run the 32bit lodctr.exe to reload the 32bit counters and the 64bit
“lodctr.exe /r “
Note: Without quotes “”
Reboot the server
Don’t forget to leave your comments 🙂
Thanks,
Aresh